The story of Vickong Dental

The management system of the hospital sense of the Vickong Dental Chain is strictly in accordance with the highest standards

 The management system of the hospital sense of the Vickong Dental is strictly in accordance with the highest standards

   Disinfection, sterilization and isolation are the basic means and important guarantees to cut off the spread of microorganisms and prevent nosocomial infections, and are also the basis of nursing work . Strengthening personnel training, emphasizing hand hygiene and standard prevention, standardizing technical operations, managing disposable medical supplies, and properly disposing of medical waste have made the infection prevention and control work of the hospital achieve a high international rating.

  The hospital sense management system mainly includes:

  1. Strictly implement the disinfection and isolation system and aseptic operation principles in the diagnosis and treatment operations, and effectively implement hand hygiene and standard prevention.

  2. Disposable examination discs are used for all visiting patients. All medical instruments that enter the patients mouth shall be disinfected or sterilized for one person, one use, one for each. All kinds of oral diagnosis and treatment instruments that come into contact with patient wounds, blood, damaged mucous membranes or enter sterile human tissue must be sterilized before use; oral diagnosis and treatment instruments that contact the patients intact mucous membranes and skin must be sterilized before use. Disinfection and sterilization items are fully marked and stored in an orderly manner in the special counter area as required.

  3. After use, the medical instruments are pretreated, recycled, cleaned, and sterilized according to the SOP for cleaning and disinfection of dental instruments.

  4. Use disposable covers for three-purpose gun, light curing, chair handle, etc. The dry can holder is changed every 4 hours, and the flushing plate is changed every day

  5. The comprehensive dental treatment table and its supporting facilities should be cleaned and disinfected every day, and should be cleaned and disinfected in time in case of pollution.

   6. High-speed mobile phone components and low-speed mobile phone components: continue to run for 20-30s after each use to discharge water and gas in the inner cavity, and at the same time, the pollutants entering the bearing and gas path can be naturally eliminated, and then collected and disposed of by the supply room. .

   7. Disinfection soaking solution management: All disinfection and sterilization soaking solutions are regularly replaced in strict accordance with the instructions for use, and the concentration of the disinfectant is monitored every day. The time of each replacement, the concentration of the disinfectant obtained by monitoring every day, and the starting time of each soaking item must be registered.

   8. Item management in restoration and orthodontic labs: Impressions, wax blocks, plaster models and various restorations in restoration labs should be soaked in 500mg/L chlorine-containing disinfectant for 5-10 minutes after each use. Rinse under running water, dry, and store in a clean container for later use.

   9. Environmental management: keep the room clean, open windows for ventilation twice a day, 20-30 minutes each time; when using air, water guns, and high-speed turbine drills, the pollution to the air and objects in the environment is relatively serious, and after use The equipment is sticky with blood, saliva, secretions, etc., which is an important medium for bacterial reproduction. Nurses are required to recycle the instruments used by doctors in a timely manner, and install dynamic and static air sterilizers that meet the requirements in the room, disinfect and register regularly. The ground and object surfaces are cleaned every day, wiped with 500mg/L chlorine-containing disinfectant, and the final disinfection treatment should be carried out after the operation every day. Establish environmental and surface disinfection registration books.

   10. Protection management: In order to better protect both doctors and patients and prevent cross-infection, doctors must wear gloves when they may come into contact with blood, blood-contaminated saliva or oral mucosa. Before diagnosing and treating each patient, it is necessary to wash hands and change new gloves. Doctors must wear masks and hats during diagnosis and treatment operations, and wear protective glasses if necessary. They should be replaced immediately when they are contaminated or wetted by liquid during operation. L Clean with chlorine-containing disinfectant towel, then wash with detergent.

   11. Strictly implement long-term management such as the classified collection of medical waste and Nissan Nissan.

   12. Strengthen monitoring: according to infection management requirements, conduct microbial monitoring of related projects for disinfection and sterilization quality of the stomatology department every quarter, such as: air, surface, sterile items, sterile soaking liquid, bacterial culture of staff hands, etc. , and check the implementation of aseptic operation at any time, and timely feedback the monitoring and inspection results to the department, analyze, evaluate and propose corrective measures for existing problems once a quarter.